Wollaston prism

沃拉斯顿棱镜

化学



双语例句

  1. The results show that measurement errors of degree of polarization change with polarization state of incident light while keeping angular error of Wollaston prism fixed.
    结果表明,在角度误差一定的前提下,偏振度测量误差随入射光偏振态的变化而变化;
  2. Calculation and analysis of the optical path difference of modified wollaston prism
    改型Wollaston棱镜的光程差及其特性分析
  3. Wollaston prism schlieren interferometer The moral value of Voss reflected in the mirror images of Voss and Laura
    沃拉斯顿棱镜纹影干涉仪从沃斯与劳拉的镜像关系看《沃斯》的精神价值
  4. Frequency mixing errors caused by the two factors existing at same time, which are elliptic polarization of laser source and installation azimuthal error of Wollaston prism, were analyzed especially in common path heterodyne interferometer.
    着重分析了在共光路外差干涉仪中由激光光源的椭圆偏振化和沃拉斯顿棱镜的安装方位角误差同时存在的情况下,引起的频率混叠综合误差的大小及变化规律。
  5. Aberration Analysis of Wollaston Prism
    渥拉斯顿棱镜的像差分析
  6. On characteristic of Wollaston prism in interferential spectroscopy
    干涉光谱仪中棱镜的分光特性
  7. New Wollaston prism system used in spectroscopy
    用于干涉光谱仪中的新型Wollaston棱镜系统
  8. On property of Wollaston prism in optical imaging system
    成像系统中Wollaston棱镜的光学性能
  9. The asymmetry of beam splitting angle of Wollaston prism is described, and the elimination of angle asymmetry of adjustable beam splitting angle prism by adjusting the cemented layer is analyzed.
    文中给出了渥拉斯顿棱镜分束角的不对称性,并对通过调整胶合介质层来消除可调分束角棱镜的不对称性进行了分析。
  10. Influence of Orientation of Wollaston Prism on Accuracy of Laser Interference Measuring System
    Wollaston棱镜方位对激光干涉测量精度的影响
  11. This paper deals with application of interferometry using a wollaston prism to visualization of flow field in the supersonic wind-tunnel.
    本文论述了Wollaston棱镜干涉法在流场显示中的应用。
  12. The accurate splitting angle of Wollaston prism and its asymmetry
    Wollaston棱镜的精确分束角及其不对称性
  13. Design of parallel and symmetric beam splitting prism based on Wollaston prism
    Wollaston式平行分束与对称分束偏光棱镜设计
  14. Symmetric polarization beamsplitting prism based on three-element Wollaston prism
    基于双Wollaston棱镜的对称分束角偏光分束镜
  15. With the view of obtaining symmetric splitting angle prism, on the basis of Bi-, through designing the orientation of the crystal optic axis rationally, make the prism plane-symmetry about center tangent plane;
    为了获得分束角对称的偏光分束棱镜,在双Wollaston棱镜结构的基础上,通过合理设计棱镜左右两端晶体光轴的取向,使棱镜整体呈中心切面对称;
  16. This new technique includes three lasers as light source, a PZT phase shifter which can push reference plane to change optical path of reference light. A large shearing Wollaston prism is placed in front of CCD camera to make interference between object wave and reference wave.
    该技术的特点是用三个激光器作为光源,一个压电陶瓷相移器产生参考光并实现相移,CCD摄像机前放置大错位剪切镜以使物光和参考光产生干涉。
  17. However, the natural characteristic of Wollaston prism provides higher polarizing performance so that this kind of detector system will reduce the error introduced by polarization mixing in detecting process, improve the quality of detected signal and simplify some optical components compared to the detector system with PBS.
    而Wollaston棱镜的自然物理特性提供了更好的分光性能,从而能降低偏振混合所带来的影响,提高了信号输出质量,并能简化接收系统中的光学元件。
  18. The Propagating Direction of Extraordinary Rays in Wollaston's Prism and Nicol's Prism
    渥拉斯顿棱镜和尼科耳棱镜中非常光线的传播方向
  19. Some formulas of phase retardation of any light passing through a Wollaston prism are given and the distribution of retardation in a special convergent beam is analysed.
    本文推导了任一空间光线经过Wollaston棱镜的相位延迟公式,分析了特殊情况下会聚光束经过棱镜的相位延迟分布。
  20. The spectral properties of the splitting angle for wollaston prism
    Wollaston棱镜分束角的光谱特性
  21. An Aberration Analysis of Wollaston Prism with Rotated Optical Axis
    转置光轴渥拉斯顿(Wollaston)棱镜的象差分析
  22. Wollaston prism with rotated optical axis and its application in multiple imaging technique
    转置光轴渥拉斯顿棱镜及其在多重成像技术中的应用
  23. Study on phase retardation of a Wollaston prism in convergent light
    Wollaston棱镜用于会聚光束中的位相延迟研究
  24. The adjustment methods for several constituents of the optical system of a common light path heterodyne interferometer are analyzed. These adjustment consists of the adjusting for incident light position, the adjusting for Wollaston prism position and the adjusting for the measured surface position.
    分析了共光路外差干涉仪光路中几个组成元件的调整方法,包括入射光位置的调整、渥拉斯顿棱镜位置的调整、被测表面位置的调整等。
  25. Studies of Polarized Prism in Spatially Modulated Interferometer
    空间调制干涉光谱仪中Wollaston棱镜的研究
  26. We must increase the transmission of the o light and the e light at the same time when we design the AR thin film of the Wollaston prism, which is different with the normal AR thin film.
    Wollaston棱镜增透膜的设计要兼顾o光e光同时增透,这是和一般基体增透膜设计的不同之处。
  27. The system includes a light source system, mainly to Wollaston prism polarizing system, detection system and data processing system in four parts.
    本系统包括光源系统,以沃拉斯顿棱镜为主的偏振系统,探测成像系统以及数据处理系统四个部分。
  28. Compared with the spectrometer based on single Wollaston prism, the new polarization imaging spectrometer has higher spectral resolution and optical throughput.
    和采用单个Wollaston棱镜的光谱仪相比,这种新型的成像光谱仪具有更高的光谱分辨率和光通量。
  29. In detail, samples are illuminated with planar polarized light, and by passing through Wollaston prism, their scattering signals are divided into two polarized lights, which are mutually perpendicular.
    具体实验中利用平面偏振光激发样品,利用渥拉斯顿棱镜,将散射的信号分成两个相互垂直的偏振光。